TM 8361 Edition 10/2011
2 Notes on safety
This operating manual contains fundamental
information which is to be observed during installation,
operation and maintenance.
It must therefore be read before installation and
commissioning!
For valves which are used in potentially explosive
areas, see Section 3
.
Installation and operation are to be performed by
qualified staff.
The area of responsibility, authority and supervision of
the staff must be regulated by the customer.
General hazard symbol!
People may be put at risk.
Safety symbol! The valve and its function
may be put at risk if this safety symbol is not
observed.
It is imperative to observe warnings and signs
attached directly to the ball valve and they are to be
kept fully legible.
The manufacturer is not responsible for and
hereby disclaims all damages resulting from a
failure to observe adequate safety precautions in
connection with the operation, maintenance and
repair of the valves!
For example, non-observance may involve the
following hazards:
Failure of important functions of the valve/plant.
Risk to people from electric, mechanical and
chemical effects.
Risk to the environment through leaks of hazard-
ous substances.
2.1 Intended use
Ball valves are on/off valves.
Richter ball valves of the series BVI/F and, BVIP/F
are pressure containing components in accordance
with the Pressure Equipment Directive (PED) for the
passage and shut-off of fluids. The valves are suitable
for vapours, gases and non-boiling liquids of group 1
according to the PED and have a corrosion-resistant
plastic lining.
Solids can lead to increased wear, damage to sealing
surfaces or to a reduction in the service life of the
valve.
The operator must carefully examine in the event of
operating data other than those provided whether the
designs of the valve, accessories and materials are
suitable for the new application (consult the manufac-
turer).
2.2 For the customer / operator
When using the valve, it must be ensured that
actuators which are retrofitted are adapted to suit
the valve
hot or cold valve parts are protected by the
customer against being touched
the ball valve has been properly installed in the
pipe system
the operating conditions stipulated in the data
sheet are not exceeded in continuous operating
mode.
This is not the manufacturer's responsibility.
Loads caused by earthquakes were not allowed for in
the design.
Ball valves at the end of a pipe (end valve)
must be sealed with a blind flange at the free
connection end and appropriately secured
against unauthorised activation.
Fire protection to DIN EN ISO 10497 is not possible
(plastic lining and plastic components).
2.3 Improper operation
The operational reliability of the valve supplied is only
guaranteed if it is used properly in accordance with
Section 2.1
of this operating manual.
The operation limits specified on the
identification plate and in the pressure-
temperature diagram must under no
circumstances be exceeded.