INSTALLATION AND OPERATING MANUAL Keep for future use! This operating manual must be strictly observed before transport, installation, operation and
Declaration about the Contamination of Richter Pumps, -Valves and Components Prepared: CRQ/Lam on: Feb. 15, 06 Page: 2 QM No.: 0912-16-2001_en/4-
Landesbank Rheinland-Pfalz, Mainz Kto. 110 145810 (BLZ 550 500 00) SWIFT: MALA DE 555 50 USt. Id. Nr. DE 811 127054 Sitz der Gesellschaft: Kempen
Series RV Page 2 9550-070-en Revision 01 TM 6751 Edition 04/2007 List of Contents List of Contents ... 2 Relev
Series RV Page 3 9550-070-en Revision 01 TM 6751 Edition 04/2007 1.1 Name plate, CE and body markings The stainless steel name plate is firmly riv
Series RV Page 4 9550-070-en Revision 01 TM 6751 Edition 04/2007 2 Notes on safety This operating manual contains fundamental informa-tion which is
Series RV Page 5 9550-070-en Revision 01 TM 6751 Edition 04/2007 3 Safety notes for applications in potentially explosive areas based on the Direct
Series RV Page 6 9550-070-en Revision 01 TM 6751 Edition 04/2007 4 Safety note for valves, certified to German Clean Air Act (TA Luft)On request, t
Series RV Page 7 9550-070-en Revision 01 TM 6751 Edition 04/2007 7 Operation 7.1 Initial commissioning Normally, the valves have been tested for le
Series RV Page 8 9550-070-en Revision 01 TM 6751 Edition 04/2007 9.2 Assembly Prior to assembly all parts are to be cleaned and the plastic-lined
Prepared: CRQ/Lam on: Feb. 15, 06 Page: 1 QM No.: 0912-16-2001_en/4-06 Approved: CRQ/Zu on: Feb. 15, 06 of : 2Safety Information / Declaration